Price 200000.0 INR/ Unit

MOQ : 1 Unit

Box Heat Exchanger Specification

  • Air Volume
  • Depends on model; 5000-25,000 m3/hr (for air-to-liquid types)
  • Thickness
  • 3-8 mm (shell wall)
  • Max. Capacity
  • Up to 100,000 kcal/hr
  • Diameter
  • Tube Diameter 16-25 mm (customizable)
  • Number of Pipe
  • Varies: typically 6-20 per module
  • Max Pressure
  • 10 Bar
  • Temperature
  • Up to 200C
  • Usage
  • Industrial
  • Condition
  • New
  • Structure
  • Box-type, Multi-layered finned tube or plate
  • Size
  • Standard
  • Liquid Flow Rate
  • 2000-10000 LPH (Liters per hour) depending on application
  • Working Presssure
  • Up to 10 Bar
  • Product Type
  • Rice Mill Dryer
  • Power
  • Not applicable (Passive heat exchanger)
  • Weight
  • Approx. 220-270 Kg (varies with size & material)
  • Dimensions
  • Customizable - 1800 x 1500 x 650 mm (Standard example)
  • Type
  • Shell and tube / Fin type
  • Port Connections
  • Flanged / threaded as per request
  • Heat Transfer Area
  • 12-50 m2 (model dependent)
  • Cleaning Method
  • Accessible covers for cleaning / Backflush capable
  • Material
  • Mild Steel / Stainless Steel / Copper / Aluminium (as per requirement)
  • Leakage Test Pressure
  • 12-15 Bar
  • Surface Treatment
  • Galvanized / Epoxy painted / Polished
  • Application
  • Industrial heating, process cooling, air handling units, HVAC, chemical plants
  • Mounting Type
  • Horizontal / Vertical
 

Box Heat Exchanger Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 1 Unit Per Week
  • Delivery Time
  • 1 Week
  • Packaging Details
  • 1 unit per week
  • Main Domestic Market
  • All India
 

About Box Heat Exchanger

Owing to our expertise in this domain, we offer Industrial Rice Mill Dryer that is utilized to dry paddy to make it alright for capacity. This item lessens grain dampness content to a level for capacity. It is made by using great quality required materials with the help of innovative technology. The provided Industrial Rice Mill Dryer is appropriately kept an eye on the different quality boundaries before dispatching it from our premises. Our customers can benefit equivalent inside the promised timeframe.



Versatile Industrial Applications

Our Box Heat Exchanger stands out as a robust solution for a range of industrial processes, including power generation, HVAC, chemical handling, and process cooling. Its design accommodates both air and liquid mediums, offering adjustable heat transfer areas and flow rates. This adaptability ensures that the exchanger efficiently supports varied operational requirements across industrial sectors.


Customizable and Durable Construction

Constructed from premium stainless steel, the heat exchanger is available in multiple sizes and configurations. Standard and custom dimensions allow seamless integration into existing systems, while surface treatments such as galvanized or epoxy coatings provide durability in harsh environments. The modular design, coupled with easy access for cleaning, ensures longevity and maintains high thermal efficiency.

FAQ's of Box Heat Exchanger:


Q: How is the Box Heat Exchanger installed and can it be mounted horizontally or vertically?

A: The Box Heat Exchanger offers flexible installation options and can be mounted both horizontally and vertically, depending on system requirements. This makes it suitable for a wide range of industrial layouts and simplifies integration into new or existing setups.

Q: What cleaning methods are available for this heat exchanger?

A: The heat exchanger is designed with accessible covers for manual internal cleaning. It is also backflush capable, allowing users to remove fouling and maintain optimal performance without full disassembly.

Q: When should I perform maintenance on the heat exchanger to ensure peak performance?

A: Routine maintenance intervals depend on the process conditions and the type of fluids used. However, periodic inspections and cleaning, as recommended in the user manual, are advised to minimize fouling and ensure high heat transfer efficiency.

Q: Where can this heat exchanger be used within industrial facilities?

A: Its robust construction and versatile design make it suitable for installation in HVAC plants, chemical processing units, industrial heating and cooling systems, and air handling units across manufacturing facilities.

Q: What are the benefits of using stainless steel and various surface treatments in this exchanger?

A: Stainless steel offers excellent corrosion resistance, ensuring longevity even when handling aggressive fluids or gases. Additional surface treatments like galvanizing, epoxy painting, or polishing further enhance resistance to harsh chemicals and environmental factors.

Q: How does the customizable design facilitate process integration?

A: With options for flanged or threaded port connections, various heat transfer areas, and adjustable dimensions, the exchanger can be tailored to fit specific flow rates, pressure, and spatial constraints, streamlining system compatibility.

Q: What is the process for testing and ensuring the exchanger's leak-proof operation?

A: Each unit undergoes rigorous leakage testing at pressures between 12 and 15 Bar prior to dispatch, assuring reliability and operational safety under maximum working pressures defined for your application.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Rice Mill Heat Exchanger Category

Rice Dryer Heat Exchanger

Rice Dryer Heat Exchanger

Price 50000.00 INR / Unit

Minimum Order Quantity : 1 Unit

Condition : New

Structure : Other, Horizontal, multipass finnedtube arrangement

Temperature : Other, Inlet temp up to 300C

Power : No direct power consumption (passive heat exchange unit) Volt (v)

Rice Processing Oil Heat Exchanger

Rice Processing Oil Heat Exchanger

Price 200000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Structure : Other, Multiple pass, finned tube bundle with support frame

Temperature : Other, Max. 220C

Power : No inbuilt power passive heat exchanger

Rice Mill Heat Exchanger

Rice Mill Heat Exchanger

Price 200000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Condition : New

Structure : Other, Multilayer tubefin arrangement

Temperature : Other, Up to 180C operating temperature

Power : Not applicable (Passive device)

Double Row Heat Exchanger

Double Row Heat Exchanger

Price 200000 INR / Unit

Minimum Order Quantity : 1 Unit

Temperature : 10C to 120C

Power : Custom According to Application



Back to top